FORTRAN/RT-11 Extensions Manual

Company:Digital Equipment Corporation
Part:AA-2124D-TC
Date:1977-10
Keywords:PDP-11

Table of Contents

  • Chapter 1 RT-11 FORTRAN Extensions
    • 1.1 What are the FORTRAN Extensions
      • Time-Interval Control and Sampling
      • Digital Input and Output
      • Analog-to-Digital (A/D) Conversion and Sampling
      • Digital-to-Analog (D/A) Conversion
      • Graph Plotting
    • 1.2 Things to Know About RT-11 and the FORTRAN Extensions
      • 1.2.1 Completion Routines
      • Considerations in Using Completion Routines
      • 1.2.2 Software Clock
      • 1.2.3 SYSLIB Library
      • 1.2.4 The RT-11 User Service Routine
      • 1.2.5 Action of CTRL/C
      • 1.2.6 Programming Requirements for High-Volume Data Acquisition
    • 1.3 Conventions
      • 1.3.1 Syntax Conventions
      • 1.3.2 Notation Conventions
    • 1.4 Description of the FORTRAN Extensions Routines
      • 1.4.1 CLRD (Clear Display) Routine
      • 1.4.2 CVSWG (Convert Switched Gain Value) Routine
      • 1.4.3 DIS (Display Data) Routine
      • 1.4.4 DRS (Digital Read-in Sampling) Routine
      • 1.4.5 DXY (Display X-Y Data Pairs) Routine
      • 1.4.6 FLT16 (16-bit Floating-Point Conversion) Routine
      • 1.4.7 FSH (Flash) Routine
      • 1.4.8 FXY (Flash X-Y Data Pairs) Routine
      • 1.4.9 HIST (Time Interval Sampling Technique) Routine
      • 1.4.10 IADC (Single Analog-to-Digital Conversion) Routine
      • 1.4.11 IDIR (Digital Input Reading) Routine
        • Reading a Digital Input Register or a Memory Location
        • Bit and Byte Manipulation of a Single Word
        • Reading the Software Clock
      • 1.4.12 IDOR (Digital Output Register) Routine
        • Loading a Digital Output Register or Memory Location
        • Reading and Resetting the Software Clock
      • 1.4.13 KB2BCD (Convert Binary to BCD) Routine
      • 1.4.14 KBCD2B (Convert BCD to Binary) Routine
      • 1.4.15 LED (LED Display) Routine
      • 1.4.16 LWAIT (Wait) Routine
      • 1.4.17 REL (Relay Control) Routine
      • 1.4.18 RTS (Repeated Sampling) Routine
      • 1.4.19 SDIS (Stop Display) Routine
      • 1.4.20 SETR (Set Rate of the Programmable Clock) Routine
    • 1.5 Building a Real-Time Support Library
      • 1.5.1 System Configuration
        • 1.5.1.1 A Standard System
        • 1.5.1.2 Changing Configuration Specifications
        • 1.5.1.3 Assembling the Revised Configuration
      • 1.5.2 The Real-Time Support Library
        • 1.5.2.1 Generating the Library
        • 1.5.2.2 Accessing the Library
    • 1.6 Error Messages
  • Chapter 2 FORTRAN Debugging Technique (FDT)
    • 2.1 Introduction
    • 2.2 Using FDT
    • 2.3 FDT Command Types
      • Program Control Commands
      • Information Transfer Commands
      • FDT Control Commands
    • 2.4 FDT Conventions and Terminology
      • Syntax Conventions
      • 2.4.1 Current Procedure
      • 2.4.2 The Location Specification
        • Offset Location
        • Named Location
        • Relative Locations
        • Subscripted Name Locations
      • 2.4.3 Mode Codes
      • 2.4.4 FDT Pause Definition
    • 2.5 Description of the FDT Commands
      • 2.5.1 ACCEPT
      • 2.5.2 CONTINUE
      • 2.5.3 DIMENSION
      • 2.5.4 ERASE
      • 2.5.5 GOTO
        • Defining a Label
      • 2.5.6 IF
      • 2.5.7 MACRO
        • Implicit Macro
      • 2.5.8 NAME
      • 2.5.9 PAUSE
      • 2.5.10 RESET
      • 2.5.11 START
      • 2.5.12 STEP
      • 2.5.13 STOP
      • 2.5.14 TYPE
      • 2.5.15 WATCH
      • 2.5.16 WHAT
    • 2.6 Cautions and Pitfalls
    • 2.7 Advanced Techniques
      • 2.7.1 Named Common
      • 2.7.2 How FDT Generates Addresses
        • Octal Offsets
        • Names
        • Relative Addressing
        • Subscript Addressing
        • Indirect Addressing
      • 2.7.3 Format Conversion Routines
      • 2.7.4 On-line Debugging Technique (ODT)
      • 2.7.5 Execution Speed
  • Appendix A Argument and Default Summary Table
  • Appendix B Object and Source Files
  • Appendix C Error Summary Table
  • Appendix D FDT Command Summary
  • Appendix E FDT Location Specification Formats
  • Appendix F FDT Modes
  • Appendix G FDT Error Messages

Copies

Address: http://bitsavers.org/pdf/dec/pdp11/fortran/AA-2124D-TC_ftnExtns_Oct77.pdf
Site: Al Kossow's Bitsavers
Format: PDF
Size: 7093622 bytes (6.8 MiB)
MD5: b02f1d8f9b0b53941e1b4c3f77f82b1b
Mirrors: